GDTL AC Resonant Test System for Generators
● Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipment.Single equipment is no more than 60kg, easy to move.
● Advanced principle of whole set device and new frequency & inductance modulation technology, strictly ensure generator power frequency withstand voltage test requirements. Wide application scope.
● Equipped with 20Hz-300Hz variable control source. Good protection and output waveform, high stability. With multiple working mode,easy to operate.
● Power supply of 220V or 380V, convenient for on-site power sourcing。
● Max.Q point can be found exactly by the mode of first inductance modulation and later frequency modulation, to avoid resonance deviation because of voltage boosting;
● Flexible configuration and strong extension. Meet all capacitive test object testing requirements in power system.
● Power frequency test mode or Variable frequency test mode.
● Multi-use, cost-effective.
Specification
● Rated output voltage: 0 ~ 50kV (RMS) or below.
● Output frequency: 45 - 300Hz.
● Waveform: pure sine wave, THD ≤ 1%.
● Max. capacity: 2000kVA or below.
● Duty cycle: continuous working 15mins one time at full power output.
● Quality factor: 10 - 40.
● Frequency adjustment sensitivity: 0.1HZ, instability of <0.05%.
● Power supply: 220V or 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 100 |
Application scope | Generator--capacitance to the ground 0.07-0.13 μF |
10 kV (300 mm² ) cable ≤ 1 km | |
Main configurations | 50kV/1A Fixed reactor 1 set |
50kV/1A Adjustable reactor 1 set | |
Capacitive divider 50kV | |
GDTF-150/50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 150 |
Application scope | Generator--capacitance to the ground 0.13-0.2 μF |
10 kV (300 mm² ) cable ≤ 1.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 1 set |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 225/50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 225 |
Application scope | Generator--capacitance to the ground 0.2-0.27 μF |
10 kV (300 mm ² ) cable ≤ 2.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 2 sets |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 360/60 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 60 |
Capacity (kVA) | 360 |
Application scope | Generator--capacitance to the ground 0.27-0.33 μF |
Main configurations | 60kV/2A Fixed reactor 1 set |
60kV/2A Adjustable reactor 1 set | |
Capacitive divider 60kV |