GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance.

facebook sharing button
twitter sharing button
linkedin sharing button
pinterest sharing button
vk sharing button
whatsapp sharing button
sharethis sharing button
Chat Now
Product Introduction

GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester

 

GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can deal with all kinds of test requirements, can measure the grounding resistance value of the large size ground down lead, flexible measuring the grounding resistance value of the single point and grid grounding and all kinds of complex grounding structure, no need to disconnect any parallel connection earth pole when measuring parallel grounding system, greatly improves the convenience of measurement, for the grounding performance test provides a perfect solution.

GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is composed of host machine, current clamp(double clamp), test wires, auxiliary ground rod, data software and communication wires and so on. The large LCD display of host machine with white backlight and bar graph indication that can be seen clearly. The tester has storage function, clock function, and automatically stores 2000 groups of test results containing date and time.The tester with Bluetooth communication function supporting Android system. After the installation of APP, can test or read test records in the mobile terminal, bringing a new experience. The tester equip USB interface, and the stored data can be uploaded to the PC through the USB interface. The communication software can realize the functions of reading, consulting, saving, reporting and printing of the historical record data. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment.

 Unique design of the jack indicator light, accurate indication of the jack position, avoid operation error.

 Gears function selection knob, various test methods are displayed, making the operation simple and fast.

 The tester has Bluetooth communication function and supports Android system. Users can use mobile terminal to test operation or read test results containing date and time very conveniently.

 The instrument case adopts waterproof protection box, which is strong, safe and durable for anti-collision, anti-fall and waterproof (protection grade IP65), especially suitable for use in outdoor construction sites.

 The meter is equipped with large capacity rechargeable lithium battery pack. And with USB interface to upload data function.


Specification

 

Basic conditions & Work conditions

Influence QuantityBase ConditionWorking ConditionsRemark
Ambient Temp23℃±1℃-10℃-40℃----
Ambient Humidity40%-60%80%----
Working Voltage7.8V±0.1VDC 7.8V±0.6V----
Auxiliary Earth Resistance100Ω5kΩ
Interference VoltageShould avoid20V
Interference CurrentShould avoid2A
Electrode Distance when  measuring Ra5da5d
Electrode Distance when  measuring ρa20ha20h

General specification

FunctionMeasure grounding resistance, soil resistivity; DC resistance, earth voltage, alternating current , leakage current
Power SupplyDC 7.4V 2600mAh rechargeable lithium battery, full of about 8.4V
BacklightControllable screen backlight, suitable for dim places
Measuring MethodDC resistanceDC resistance 2-wire method
DC resistance 4-wire method
Earth resistanceEarth resistance 2-wire method
Earth resistance 3-wire method
Earth resistance 4-wire method
Earth resistance single clamp 3-wire method (selection method)
Earth resistance single clamp 4-wire method (selection method)
Earth resistance double clamp method
Soil resistivity(Wenner method)
Earth currentCurrent clamp measurement
Earth voltageAverage rectification
Test Voltage WaveSine wave
Test Frequency128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test CurrentAC 250mA max
Open-circuit Test CurrentAC 40V max
Electrode Distance Range1m-100m
Display Mode4-digital large LCD display, with screen backlight
Measuring IndicatorDuring measurement, LED flash indicator, LCD countdown display
LCD Frame Dimension128mm×75mm
LCD display area124mm×67mm
Instrument Dimension280mm(L) X 260mm(W) X 160mm(H)
CT Size223mm X 120mm X 39mm
Test Wire4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire2 wires: each for red 1.6m and black 1.6m
Auxiliary Grounding Rod4PCS: Φ10mm X150mm
Current Clamp2PCS :1 blue-black plug and 1 red-black plug
Clamp CaliberΦ70mm
Clamp Lead Wire2m
Measuring RateAC current: about 2 times/second
Earth Voltage: about 2 times/second
Earth resistance: about 7 seconds/time
Measuring TimesOver 5000 times (Short-circuit test, interval time should be at least 30 seconds)
Line VoltageMeasurement below AC 600V
Communication InterfaceBluetooth module, USB interface, storage data can be uploaded to computer, saved or printed.
Communication WireUSB communication wire x1pcs, with length 1.5m
Data HoldData hold function: "HOLD" symbol display
Data Storage2000 groups, “MEM” storage indicator, "FULL" symbol flash display storage is full
Data AccessData read function:"READ" symbol display
Overflow DisplayExceed measuring range overflow function: "OL"symbol display
Low Current Indicator of Current clampMeasurement with selection method or double clamp, the current signal received by CT2 is lower than 0.5mA,will display“    ”, and should check the clamping direction of the CT2 current clamp
Interference TestAutomatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Auxiliary Grounding TestWith auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm FunctionMeasuring value exceeds alarm setting value, will make out "Toot-toot-toot" alarm sound.
Battery VoltageWhile battery voltage decreases to around 7.2V±0.1V, will display battery voltage low symbol, and reminding to replace the battery
Automatic ShutdownAutomatically shut down after 15 minutes of power on
Working CurrentBacklight: 25mA Max(only backlight power consumption)
Standby:25mA Max(Backlight off after power on)
Measurement:150mA Max(Backlight shut off)
WeightTester: 2290g
Current Clamp:1100g(2pcs)
Total weight: 6800g(include all accessories)
Working Temperature & Humidity-10℃-40℃, below 80%rh
Storage temperature & humidity-20℃-60℃, below 70%rh
Protection LevelIP65(close the case)
Overload ProtectionMeasure earth resistance: between each interfaces of C(H)-E, P(S)-ES, AC 280V/3 seconds
Insulation ResistanceOver 20MΩ(between circuit and outside shell is 500V)
Withstanding VoltageAC 3700V/rms. (Between circuit and outside shell)
Electromagnetic FeaturesIEC61326(EMC)
Protection TypeIEC61010-1(CAT Ⅲ 300V, CAT IV 150V, Pollution 2);
IEC61010-031;
IEC61557-1(Earth resistance);
IEC61557-5(Soil resistivity);
JJG 366-2004(Grounding resistance meter)
JJG 1054-2009(Clamp grounding resistance meter)


Send Inquiry