Product Introduction

GDYD-D AC Dielectric Test Equipment With Manual Control Unit

 

 Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend.
 Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing.
 Over-current protection, zero-starting protection, sound, and light alarm.
 Continuously variable output from zero to full voltage.
 Adjustable over current protection, with trip levels variable from 10 to 110%.
 With new type time relay, time range is wider (1S ~ 99H).
 Using the latest current relay, more accurate and reliable.
 Light weight, small size, easy to move.

Specification

 

 Input voltage: AC 220V or 380V
 Output voltage of control unit: AC 0-250V or 0-430V
 Output current of control unit:0-5/10/15/50A(customized)
 Capacity: 0-3/5/10/15/20/30/50/100kVA(customized)
 Output voltage of HV unit: 0-50/100/150/200kV(customized)
 Output current of HV unit: 0-50/100/150/200/500/1000/2000mA(customized)
 Timing: 0-9999s
 Environmental temperature: -20℃--50℃
 Voltage accuracy: ≤ 1.5%±1digit (F.S)
 Current accuracy: ≤ 1.5%±1digit (F.S)