GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis.

facebook sharing button
twitter sharing button
linkedin sharing button
pinterest sharing button
vk sharing button
whatsapp sharing button
sharethis sharing button
Chat Now
Product Introduction

GDPQ-300E Power Quality Analyzer

 

Meter detection functions

NoItemsDescription
1Voltage/Current/FrequencyIt can measure three-phase voltage, zero line voltage, three phase current, zero line current, frequency. Can display RMS, peak value, wave/peak ratio, waveform, Trend charts etc.
2Harmonic wave measurementIt can measure fundamental wave of voltage and current and 2~50 times harmonics wave. The measurement results include harmonic efficiency, harmonic content, harmonic content, and total harmonic distortion (THD). Histograms and trends charts, etc.
3Interharmonic measurementIt can measure 0.1 ~ 19.9 times interharmonics of voltage and current. The measurement results include the interharmonic components and the effective values of the subset, the interharmonic content rate etc. it can display histograms, trend charts, etc.
4Power measureIt can measure three-phase four-wire/three-phase three-wire  apparent power (electric energy), active power (electric energy), reactive power (electric energy), power factor etc., it can display trend chartscan measure demand of 1, 5, 10, 15, 30 60 minutes.
5Three phase unbalance measureIt can measure three-phase four-wire / three-phase three-wire electrical system voltage and current positive sequence component, negative sequence component, zero sequence component, negative sequence imbalance degree, zero sequence imbalance degree; phase angle of three phase voltage and current , vector, trend charts.
6Flicker1 minute flicker, 10 minute short flicker, 2 hour long flicker measurement
7Voltage Swell / Dip / InterruptionDetects and logs voltage swells, sags and interruptions events.
8Surge currentDetects and logs surge current events
9Harmonic powerCan detect 2 ~ 30 times harmonic power, can display histogram, trend charts, etc.
10Power waveCan measure the rapid change of power (active, reactive, apparent power) according to the set time (1 ~ 5 minutes)
11TransientsCan detect voltage transients longer than 20 microseconds
8Monitoring recordIt can record steady-state power quality parameters for a long time, including voltage / current / frequency, harmonics, power, three-phase imbalance, fluctuation / flicker, and the recording interval can be adjusted from 3 seconds to 30 minutes.
9Digital oscilloscopeView voltage/current signal wave form

Each accuracy index for detection functions

ItemMeasure rangeMeasure accuracyRemark
Voltage/current
/frequency
Three phase voltage:  1000V(effective value)
Zero line voltage : 70V (effective value)
Three phase current : 6000A(effective value,1000A current sensor for optional)
Zero line current : 25A (effective value)
Frequency: 40-70Hz
Voltage: 0.1%rdg ±0.05%f.s
Current: 0.2%rdg ±0.05%f.s
Frequency: reading±0.01Hz
 
Here,we use A phase voltage frequency as measure frequency
Harmonic wave measureVoltage harmonic: THD+ Fundamental wave + 2-50times harmonic wave.
Current harmonic: THD+ Fundamental wave + 2-50times harmonic wave.
Voltage harmonic wave:
Uh1%UN,±5%Uh
Uh1%UN,±0.05%UN
Current harmonic wave:
Ih3%IN,±5%Ih
Ih3%IN,±0.15%IN

Inter harmonic wave measureVoltage harmonic: 0.1~19.9 times Inter harmonic wave .
Current harmonic: 0.1~19.9 times Inter harmonic wave
Voltage Inter harmonic wave:
Uih1%UN5%Uih
Uih1%UN0.05%UN
Current Inter harmonic wave:
Iih3%IN5%Iih
Iih3%IN0.15%IN

Power / Electric energyActive power: 700kVA
Reactive power: 700kVAR
Power factor: 0.00~1.00
Active power energy: 10000kWh
Apparent power energy: 10000kVAh
Reactive power energy: 10000kVARh
Average power factor: 0.00-1.00
Active: reading±0.5%
Apparent: reading±0.5%
Reactive: reading±0.5%
Power factor: reading±0.005
 

Three phase unbalanceFundamental voltage: 1000V(effective value)
Fundamental current: 6000A(effective value)
Fundamental frequency: 40-70Hz
Phase angle: 0-360degree
Unbalance: 0.0%-100%
Voltage: 0.1%rdg ±0.05%f.s
Current: 0.2%rdg ±0.05%f.s
Frequency: reading±0.01Hz
Phase angle: reading±0.3degree
Voltage unbalance: reading±0.2%
Current unbalance: reading±0.2%
Here,we use A phase voltage frequency as total measurement frequency
 
Voltage Flicker1 minutes flicker, short time flicker, long time flicker1 minutes flicker: ±5.5%
10 minutes short flicker: ±5%
2 hours long time flicker: ≤±5%

Voltage swell, dip and interruptMonitor and record single-phase/multi-phase voltage swell, voltage dip and temporary power-offHalf-wave RMS, start time, duration, end time error ±10msUp to 40 event records
Surge CurrentMonitor and record single-phase/multi-phase surge currentsHalf-wave rms value, start time, duration, end time time error ±10msStop measuring when capturing an event
Harmonic wave powerTotal harmonic power times: 1~30th
Harmonic total active power: P
Harmonic total reactive power: Q
Positive harmonic total active power: +P
Negative harmonic total active power: -P
Positive harmonic total reactive power: +Q
Negative harmonic total reactive power: -Q
Harmonic power reading: ±0.5%
Power waveIt can detect 1, 3, 5 minutes length of active, reactive, apparent half-wave power value, recording power change trendHalf-wave power reading: ±0.5%
TransientVoltage transients based on a nominal value of more than 120%1.the minimum period of measurable events is more than 20 microseconds
2. the probability of event capture 98.7%
20 events can be stored in one measurement
Monitoring recordRecord parameters include voltage, current, frequency, voltage/current harmonic wave(total harmonic+1-25 times harmonic), three-phase unbalance; active/reactive/apparent power, power factor; fluctuation/flicker Data storage interval: 3s~30min
The interval is 3s, and the total monitoring time is 16h;
The interval is 30min, and the total monitoring time is 960h.

Digital oscilloscopeThree phase voltage, three phase current, zero line voltage and zero line current instant wave formMax. sampling frequency: 200kHz
Min. sampling frequency: 100Hz


Specification

 

 Voltage signal input loop:
Direct access, input impedance: 1MΩ, 20pF
Measure range: voltage effective value 1000V
Power consumption: less than 0.5VA/phase
 Current input loop:
Indirect access
Measure range: Current effective value 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (select corresponding current sensor)
Power consumption: Less than 0.5VA/phase
 Measure signal frequency range: 40Hz-70Hz
 Display screen: 5.7 inch 640 *480 color LCD with touch screen
 Memory storage: 128M byte FLASH
 Outside storage port: USB ( plug in USB disk)
 Working power supply: Rechargeable Li-battery, 5-6hours working time for full charge
 Power supply: AC100-240V/DC 16.8V-1A power adapter/charger

Send Inquiry